Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13637139

- Product Categories
- Friendly Links
Information Name: | POLYCOLD manufacturers |
Published: | 2015-01-30 |
Validity: | 3000 |
Specifications: | TY-DW-3500 |
Quantity: | 888.00 |
Price Description: | |
Detailed Product Description: | Refrigeration Equipment Manufacturers POLYCOLD Yu-fei Tianyi Science and Technology Co., Ltd. since its inception, has been specializing in ultra-low temperature equipment research, development and production of high-tech enterprises, the company has developed a number of professional dual cascade refrigeration, single auto-cascade design team refrigeration equipment, enterprises through ISO9001, CE and other quality system certification, is in the field of cryogenic production, technology strongest high-tech enterprises. POLYCOLD refrigeration equipment factory Yu-fei Tianyi Science and Technology Co., Ltd. Tianyi overtemperature "TY-DW" series of ultra-low temperature products are completely independent intellectual property rights, long-term major vacuum coating machine manufacturers, Aerospace Research Institute, the national environmental monitoring and other projects 863 provide -120 ℃ ~ -150 ℃ ultra-low temperature test equipment. Main products: POLYCOLD manufacturers -145 ℃ cryogenic trap pump, -90 ℃ ultra-low temperature cold trap rod (Parylene vacuum coating cold trap), - 90 ℃ pot ultra-low temperature cold trap, -135 ℃ ultra-low temperature cold trap rod, -135 ℃ ultra-low temperature cold trap pan, metal chilling treatment tank, rapid cycling condensation pump (polycold), - 145 ℃ water vapor trap pump (low temperature cold trap), - 60 ℃ to -150 ℃ ultra-low temperature refrigeration units, -60 ℃, - 86 ℃, -120 ℃, -150 ℃ series of ultra-low temperature freezer,? cryogenic liquid bath, such as ultra-low temperature equipment. Products are widely used in vacuum coating, research institutes, health care, military aviation, pharmaceutical, universities electronics, metal processing industries. Application of the principle: POLYCOLD manufacturers in the high vacuum environment, there is a certain degree of residual gas. Since water has a molecular weight of less than molecular oxygen, nitrogen and other major components of air, therefore, whether or molecular diffusion pump oil pump, they can not quickly and effectively pull it out, therefore piled up, finally becoming the residual gas accounts for 65% ~ 95% of the residual gas; Meanwhile, since the vacuum pump in the course of which is caused by the evaporation of the oil pump, there will be a small amount of oil vapor into the vacuum system. A due to the presence of water vapor and oil vapor, causing the vacuum system can not quickly reach the customer with the desired degree of vacuum, resulting in evacuation time becomes longer, the production efficiency drops, a desired degree of vacuum higher the humidity, the more obvious impact . Second, at the same time, water vapor, the presence of oil vapor will cause the film decreased firmness, can not multi-coated, color uneven first-class. Three steam will, under certain conditions ionization, produce oxygen, so that the target oxide, resulting in coating color change. Ambient humidity, the higher the temperature, the higher the desired degree of vacuum, the greater the effect. Therefore, steam, oil field steam vacuum coating and high vacuum to obtain a gas main hazard areas. POLYCOLD manufacturers cryogenic trap gas pump and vacuum pumping different, he is able to reach -120 ℃ following a cooling coil, cabinets or placed in a vacuum diffusion pump oil pump port, use Meissner principle, the water vapor, oil vapor rapid condensation in the cooling coil surface to achieve rapid evacuation, increase productivity, improve quality coating purposes. Therefore, the low temperature trap vacuum pump is used in conjunction with, compared to using a separate vacuum pump will substantially increase productivity, improve product quality. Rapid absorption of water vapor in the vacuum system, oil vapor, effectively shortening the evacuation time of 30% to 90%, improve the coating quality, completely solve the film uneven color, easy off phenomenon. Reasons steam, oil vapor and other residual gases generated: in a high vacuum environment, there is a certain degree of residual gas. Since water has a molecular weight of less than molecular oxygen, nitrogen and other major components of air, therefore, whether or molecular diffusion pump oil pump, they can not quickly and effectively pull it out, therefore piled up, finally becoming the residual gas accounts for 65% - more than 95% of the remaining gas; at the same time, due to the vacuum pump in the course will inevitably produce pump oil evaporation phenomenon, and therefore there will be a small amount of oil vapor into the vacuum system. Cryogenic trap pump applications principle: cryogenic trap gas pump and vacuum pumping different, he is able to reach -120 ℃ following a cooling coil, cabinets or placed in a vacuum diffusion pump oil pump port, use Meissner principle, water vapor, oil vapor condenses rapidly cooling coil surface to achieve rapid evacuation, increase productivity, improve the quality of the purpose of the coating. Therefore, the low temperature trap vacuum pump is used in conjunction with, compared to using a separate vacuum pump will substantially increase productivity, improve product quality. POLYCOLD manufacturers Tianyi - low temperature (TY-DW) Series cryogenic trap pump main features: POLYCOLD manufacturers cool quickly, within three minutes cooling to -120 ℃, the lowest up to -145 ℃; rapid adsorption of water vapor, oil vapor, shortening evacuation time from 60% to 95%; 3 minutes hot gas defrost, warmed rapidly; control system with touch screen + Siemens PLC, more grades; with local control, remote control interface, compatible with any vacuum system, customers can access Coater automatic control system; standby temperature indicator; maintain long-term continuous operation; a piece of equipment can be designed dual load output; can be designed dual load outlet and return port temperature display, the machine temperature display; imported brands dedicated cryogenic compressors, each types of control valves using imported components, stable and reliable operation; high pressure compressor protection, exhaust temperature protection; easy to install, simple system transformation; power, high water temperature alarm and protection; compact structure, small size, light weight POLYCOLD manufacturers Tianyi - low temperature (TY-DW) Series cryogenic trap pump Parameter Model TY-DW-2000 TY-DW-2500 TY-DW-3500 coil temperature (℃) -120 ℃ to -145 ℃ compressor power ( KW) 8 10 12 pumping speed (l / s) 100000 150000 250000 heat load (W) 2000 2500 3500 coil surface area (m2) 0.7 1.0 2.0 coil specifications 14m, φ16mm 20m, φ16mm 40m, φ16mm pre-cooling time (min ) ≤30 ≤30 ≤30 cooling time (min) ≤5 ≤5 ≤5 defrosting time (min) ≤3 ≤3 ≤3 longer cooling time (min) ≤5 ≤5 ≤5 output single output Single / Dual Output Single / Dual Output applicable furnace volume 2m3 3 m3 6 m3 Cooling water (t≤30 ℃) Power 380V 50HZ Dimensions mm (W x D x H) 800 X800 X1620 800 X800 X1620 900 X1000 X1750 weight (Kg) 400 450 500 POLYCOLD manufacturers |
Admin>>>
You are the 12044 visitor
Copyright © GuangDong ICP No. 10089450, Yu-fei Tianyi Refrigeration Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 12044 visitor
Copyright © GuangDong ICP No. 10089450, Yu-fei Tianyi Refrigeration Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility