Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13637139

- Product Categories
- Friendly Links
Information Name: | Cryogenic trap pump |
Published: | 2015-01-30 |
Validity: | 3000 |
Specifications: | Cryogenic trap pump |
Quantity: | 888.00 |
Price Description: | |
Detailed Product Description: | Cryogenic pump cryogenic trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap pump POLYCOLD fei Tianyi Refrigeration Equipment Co., Ltd. Since its establishment, has been specializing in the development of ultra-low temperature equipment, development, Production of high-tech enterprises, the company has developed a number of professional dual cascade refrigeration, single auto complex cascade refrigeration equipment designers team, enterprises through ISO9001, CE and other quality system certification, is in the field of production of ultra-low temperature Technical strongest high-tech enterprises. Yu-fei Tianyi Refrigeration Equipment Technology Co., Ltd. Tianyi overtemperature "TY-DW" series of ultra-low temperature products are completely independent intellectual property rights, long-term major vacuum coating machine manufacturers, Aerospace Research Institute, the National 863 environmental monitoring projects - 120 ℃ ~ -150 ℃ ultra-low temperature test equipment. Cryogenic pump cryogenic trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap pump POLYCOLD main products: -145 ℃ cryogenic trap pump, -90 ℃ rod ultra-low temperature cold trap (Parylene vacuum coating cold trap), - 90 ℃ pot ultra-low temperature cold trap, -135 ℃ rod ultra-low temperature cold trap, -135 ℃ pot ultra-low temperature cold trap, metal chilling treatment tank, rapid cycling condensation pump (polycold), - 145 ℃ water vapor trap pump (low temperature cold trap), - 60 ℃ to -150 ℃ ultra-low temperature refrigeration units, -60 ℃, -86 ℃, -120 ℃, -150 ℃ series of ultra-low temperature freezer, cryogenic liquid bath, such as ultra-low temperature equipment?. Products are widely used in vacuum coating, research institutes, health care, military aviation, pharmaceutical, universities electronics, metal processing industries. Pot cold trap cryogenic pump price cryogenic trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap POLYCOLD pump application principle: in a high vacuum environment, there is a certain degree of residual gas . Since water has a molecular weight of less than molecular oxygen, nitrogen and other major components of air, therefore, whether or molecular diffusion pump oil pump, they can not quickly and effectively pull it out, therefore piled up, finally becoming the residual gas accounts for 65% ~ 95% of the residual gas; Meanwhile, since the vacuum pump in the course of which is caused by the evaporation of the oil pump, there will be a small amount of oil vapor into the vacuum system. A due to the presence of water vapor and oil vapor, causing the vacuum system can not quickly reach the customer with the desired degree of vacuum, resulting in evacuation time becomes longer, the production efficiency drops, a desired degree of vacuum higher the humidity, the more obvious impact . Second, at the same time, water vapor, the presence of oil vapor will cause the film decreased firmness, can not multi-coated, color uneven first-class. Three steam will, under certain conditions ionization, produce oxygen, so that the target oxide, resulting in coating color change. Ambient humidity, the higher the temperature, the higher the desired degree of vacuum, the greater the effect. Therefore, steam, oil field steam vacuum coating and high vacuum to obtain a gas main hazard areas. Cryogenic pump cryogenic trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap POLYCOLD pump and vacuum pump cryogenic trap different pumping gas, he was able to achieve a below -120 ℃ The cooling coil, cabinets or placed in a vacuum diffusion pump oil pump port, use Meissner principle, the water vapor, oil vapor condenses rapidly cooling coil surface to achieve rapid evacuation, increase productivity, improve quality coating purposes . Therefore, the low temperature trap vacuum pump is used in conjunction with, compared to using a separate vacuum pump will substantially increase productivity, improve product quality. Rapid absorption of water vapor in the vacuum system, oil vapor, effectively shortening the evacuation time of 30% to 90%, improve the coating quality, completely solve the film uneven color, easy off phenomenon. Cryogenic pump cryogenic trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap POLYCOLD pump main characteristics: cool quickly, within three minutes cooling to -120 ℃, the lowest up to -145 ℃; rapid adsorption of water vapor, oil vapor, shorten evacuation time from 60% to 95%; 3 minutes hot gas defrost, warmed rapidly; control system with touch screen + Siemens PLC, more grades; with local control, remote control interface compatible with any vacuum system, clients can access Coater automatic control system; standby temperature indicator; maintain long-term continuous operation; one device can be designed dual load output; can be designed dual load outlet and return port temperature display, the machine temperature display; imported brands dedicated cryogenic compressors, various control valves using imported components, stable and reliable operation; high pressure compressor protection, exhaust temperature protection; easy to install, simple system transformation; power, high temperature alarm protect; compact structure, small size, light weight, ultra-low temperature cryogenic pump trap trap trap cryogenic pump cryogenic cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap pump POLYCOLD Tianyi - low temperature (TY-DW) Series cryogenic trapping pump parameter table model TY-DW-2000 TY-DW-2500 TY-DW-3500 coil temperature (℃) -120 ℃ to -145 ℃ compressor power (KW) 8 10 12 pumping speed (l / s ) 100000 150 000 250 000 thermal load (W) 2000 2500 3500 coil surface area (m2) 0.7 1.0 2.0 coil specifications 14m, φ16mm 20m, φ16mm 40m, φ16mm pre-cooling time (min) ≤30 ≤30 ≤30 cooling time (min) ≤5 ≤5 ≤5 defrosting time (min) ≤3 ≤3 ≤3 longer cooling time (min) ≤5 ≤5 ≤5 output single output Single / Dual Output Single / Dual Output applicable furnace volume of 2m3 3 m3 6 m3 Cooling water (t≤30 ℃) Power 380V 50HZ Dimensions mm (W x D x H) 800 X800 X1620 800 X800 X1620 900 X1000 X1750 Weight (Kg) 400 450 500 cryogenic pump cryogenic trap catch Set pump cryogenic trap ultra-low temperature cold trap POLYCOLD manufacturers POLYCOLD maintenance POLYCOLD POLYCOLD domestic sales agent vapor trap pump POLYCOLD Tianyi - low temperature (TY-DW) -90 ℃ ultra-low temperature cold trap pan Tianyi - low temperature (TY-DW) -90 ℃ Ultra-low temperature cold trap rod Yu-fei Tianyi Refrigeration Equipment Technology Co., Ltd. Tianyi - low "TY-DW" series of ultra-low temperature products are completely independent intellectual property rights, long-term major vacuum coating machine manufacturers, Aerospace Research Institute, the National Environment 863 monitoring projects -120 ℃ ~ -150 ℃ ultra-low temperature test equipment. Main products: -145 ℃ cryogenic trap pump, -90 ℃ ultra-low temperature cold trap rod (Parylene vacuum coating cold trap), - 90 ℃ pot ultra-low temperature cold trap, -135 ℃ ultra-low temperature cold trap rod, -135 ℃ pot ultra-low temperature cold trap, metal chilling treatment tank, rapid cycling condensation pump (polycold), - 145 ℃ water vapor trap pump (low temperature cold trap), - 60 ℃ to -150 ℃ ultra-low temperature refrigeration units, -60 ℃, -86 ℃ , -120 ℃, -150 ℃ series of ultra-low temperature freezer,? cryogenic liquid bath, such as ultra-low temperature equipment. Products are widely used in vacuum coating, research institutes, health care, military aviation, pharmaceutical, universities electronics, metal processing industries. |
Admin>>>
You are the 12044 visitor
Copyright © GuangDong ICP No. 10089450, Yu-fei Tianyi Refrigeration Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 12044 visitor
Copyright © GuangDong ICP No. 10089450, Yu-fei Tianyi Refrigeration Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility